Moderators: chossmonkey, Dom, granite_grrl
Ulysse wrote:I do for ice and mixed climbing or anywhere where severe forces might happen. The only thing I add to system is a knot on each strand instead of the entire focal point. The system is more or less protected from extention since the the knot gets jammed in the binner if an anchor fails. Works well as long as the knots are close to the focal point. The main drawback is the aprox 30% reduction in sling strenght from the knots and a limited range of motion of the sliding x if the knots are to close to the biner. Also, you might want to consider a figure 9 or someting thats easy to untie after loading.
martha wrote:I use it on climbs that have two good bolts, especially if the route is going to get top roped by beginners who tend to wander back and forth a bit. I use two slings for it though.
Greg H wrote:
I like the idea of using two slings to solve the redundancy problem but the potential of shock loading still exists if one of the anchor points fails.
martha wrote:Most of the time Fred and I use 2 quick draws as anchors on sport routes (in Greenlaw that is pretty well all we use unless we know that a lot of people are going to be top roping on it)... one person leads up, sets a quick anchor of 2 draws and the other either pulls the rope and re-leads or top ropes through the draws. You save a TON of time and can get more climbing in. It is all A-OK with me.
Shawn B wrote:Give me one good solid reason for not using lockers.
Fred wrote:Greg: I would say, use the "x" (with two slings) if you want and re-focus your energy on barking at bad belayers and making sure you remembered to tie-in. That's more likely where you'll slip-up and get hurt.
Shawn B wrote:And Greg...regarding the sliding x...search back a few months. Burley and I discussed the benefits of both and I posted a link to a real good article on anchors. There is no one absolute perfect solution for all anchors. At least one variable will always be compromised. The limiting knots do help some in the sliding x though. I think both are good options to have in your anchor arsenal. Like Cara said though double up the sling if using a sliding x.
Greg H wrote:Speaking of refocusing energy Fred, aren't you supposed to be out somewhere chasing cougars?
Fred wrote:Shawn: you do tend to be on the other extreme end of caution...
Shawn B wrote:martha wrote:Most of the time Fred and I use 2 quick draws as anchors on sport routes (in Greenlaw that is pretty well all we use unless we know that a lot of people are going to be top roping on it)... one person leads up, sets a quick anchor of 2 draws and the other either pulls the rope and re-leads or top ropes through the draws. You save a TON of time and can get more climbing in. It is all A-OK with me.
IMNSHO you are endorsing a "not-so-safe" practice Cara. Yes it seems to be a well accepted practice at sport climbing venues. Just something I myself have never been comfortable with. Can anyone tell me why it seems accepted in sport climbing yet if you saw a trad climber using a single non-locker on an anchor you'd call it sketch. Gravity doesn't know if you are sport climbing or trad climbing. And whacky things can happen. So really how much harder is it to rig a couple of shoulder length slings with a locker on each end and clip the anchor with that vs just a standard quick draw. Heck rig a couple of dogbones with lockers and use those if the shoulder length are a pain. I always have one of these and clip the first bolt with it due to the varying angles which can be placed on the first piece (I call it my slowdraw). Why not stack the odds in your favour? Is it worth a few extra seconds of time and the price of 4 lockers for your kids to have a mommy?
And Greg...regarding the sliding x...search back a few months. Burley and I discussed the benefits of both and I posted a link to a real good article on anchors. There is no one absolute perfect solution for all anchors. At least one variable will always be compromised. The limiting knots do help some in the sliding x though. I think both are good options to have in your anchor arsenal. Like Cara said though double up the sling if using a sliding x.
Andrew wrote: Two sliding X anchors each with their own biner.
*Chris* wrote:Ha... is it too late for Burley and I to get into this debate?
Greg... for TR... I used to use the sliding x on two slings but honestly... any route wandering that much should probably have directional pieces on it anyway. It's a good tool to know however and I use it often as part of gear anchors. I will say this however... how is it possible for a bolt to be "shock-loaded" if a top rope fall leads to an X extending a foot or two... given the amount of dynamic rope in the system?
Fred wrote:Greg:
It's been brought to my attention that perhaps my comment to watch your belayer might have been interpreted as a crack at Stacey. I assure you it was a general comment to keep your eyes on all belayers. The thought never crossed my mind when I wrote that original post. I'd let Stace belay me anyday.
Cheers
Greg H wrote:*Chris* wrote:Ha... is it too late for Burley and I to get into this debate?
Greg... for TR... I used to use the sliding x on two slings but honestly... any route wandering that much should probably have directional pieces on it anyway. It's a good tool to know however and I use it often as part of gear anchors. I will say this however... how is it possible for a bolt to be "shock-loaded" if a top rope fall leads to an X extending a foot or two... given the amount of dynamic rope in the system?
If one bolt blows on a two bolt sliding x anchor there will suddenly be slack in the anchor sling and it will extend, possibly causing the rest of the anchor (1 bolt) to be shock loaded. This would happen only if the limiter knots weren't tied in the sling. The sliding x with one sling goes against two aspects of SRENE - Redundant and NonExtending. However.....with just one sling tied with two limiter knots the sliding x meets all the requirements of SRENE.
How was Gunkland?
Greg H wrote:*Chris* wrote:Ha... is it too late for Burley and I to get into this debate?
Greg... for TR... I used to use the sliding x on two slings but honestly... any route wandering that much should probably have directional pieces on it anyway. It's a good tool to know however and I use it often as part of gear anchors. I will say this however... how is it possible for a bolt to be "shock-loaded" if a top rope fall leads to an X extending a foot or two... given the amount of dynamic rope in the system?
If one bolt blows on a two bolt sliding x anchor there will suddenly be slack in the anchor sling and it will extend, possibly causing the rest of the anchor (1 bolt) to be shock loaded. This would happen only if the limiter knots weren't tied in the sling. The sliding x with one sling goes against two aspects of SRENE - Redundant and NonExtending. However.....with just one sling tied with two limiter knots the sliding x meets all the requirements of SRENE.
How was Gunkland?
Exactly. Lets say you manage to somehow blow a bolt on a TR fall... perhaps the hanger spins off... let's be generous and say you're going to freefall 3 meters due to extension and an asleep belayer. Typically on a top rope setup you're going to have at least 30m of rope in the system.martha wrote:Greg H wrote:*Chris* wrote:Ha... is it too late for Burley and I to get into this debate?
Greg... for TR... I used to use the sliding x on two slings but honestly... any route wandering that much should probably have directional pieces on it anyway. It's a good tool to know however and I use it often as part of gear anchors. I will say this however... how is it possible for a bolt to be "shock-loaded" if a top rope fall leads to an X extending a foot or two... given the amount of dynamic rope in the system?
If one bolt blows on a two bolt sliding x anchor there will suddenly be slack in the anchor sling and it will extend, possibly causing the rest of the anchor (1 bolt) to be shock loaded. This would happen only if the limiter knots weren't tied in the sling. The sliding x with one sling goes against two aspects of SRENE - Redundant and NonExtending. However.....with just one sling tied with two limiter knots the sliding x meets all the requirements of SRENE.
How was Gunkland?
I think what Chris was getting at is that in a top rope system with 30+ meters of dynamic rope out, a shock loading situation should one anchor bolt fail is unlikely. the rope itself would absorb much of the shock.
PeterA wrote:
Even with limiter knots there will still be schockloading, just not as much. They're limiting knots, not eliminating knots And no anchor truly meets all of the SRENE guidelines.
-PJ
*Chris* wrote:Exactly. Lets say you manage to somehow blow a bolt on a TR fall... perhaps the hanger spins off... let's be generous and say you're going to freefall 3 meters due to extension and an asleep belayer. Typically on a top rope setup you're going to have at least 30m of rope in the system.
Fall distance / Rope length = fall factor = 0.1
How does a 0.1 fall factor = a " shock load " on the remaining bolt?